Skip to content

Material group · ASME B16.5 / EN 1092-1

Carbon Steel Flanges & Forgings — A105, A350 LF2, A694

Carbon steel is the default material for oil, gas, water and steam piping: adequate strength, good weldability and the lowest cost of the B16.5 material groups.

Carbon steel weld neck flange technical drawing

ASTM A105 is the standard forged carbon steel for flanges and fittings in ambient-to-moderate service. It is used across Class 150 to 2500 and is readily weldable, machinable and available in the full B16.5 size range. For low-temperature service down to −46 °C, A350 LF2 is the specified grade because it is impact-tested at low temperature. For higher yield strength in pipelines, A694 F52, F60, F65 and F70 are used with matching pipe grades.

Carbon steel flanges are normally supplied with a black oxide or anti-rust oil finish. Galvanising, epoxy or zinc-rich paint can be applied for atmospheric or buried service. We stock A105 in the common sizes and machine A350 LF2 and A694 grades to order, with MTC 3.1, heat-number marking and PMI verification on request.

Grades we machine and forge

Grade Specification Service temperature Typical use
ASTM A105 ASME B16.5 Group 1.1 −29 to 425 °C General piping, steam, water, oil and gas
ASTM A105N Normalised A105 −29 to 425 °C Improved toughness for low-temperature or impact-tested duty
ASTM A350 LF2 Low-temperature carbon steel −46 to 345 °C Cold-service piping, LNG and refrigeration
ASTM A694 F52 High-yield pipeline flange −29 to 400 °C Transmission pipelines, high-pressure gas
ASTM A694 F60 High-yield pipeline flange −29 to 400 °C High-strength line pipe connections
Q235B / 20# GB/T 9112–9124 −20 to 350 °C Domestic and general industrial piping

Selection notes

  • A105 is not recommended for wet sour service without hardness control and NACE MR0175 compliance.
  • For service below −29 °C specify A350 LF2 with impact testing at the design temperature.
  • Carbon steel flanges are supplied with anti-rust oil by default; painting or galvanising is available on request.

Welding and fabrication

  • A105 welds readily with common carbon steel consumables; preheat is generally not required below 25 mm wall thickness, but thicker sections benefit from 100–150 °C preheat.
  • Post-weld heat treatment is not mandatory for A105 in most services, but is specified where the joint is thick, restrained or exposed to sour service.
  • A350 LF2 should be welded with low-hydrogen consumables and a controlled heat input to preserve low-temperature toughness.
  • Galvanising is common for atmospheric and buried service; machined faces are usually masked to keep the gasket surface clean.

How to order

  • State the standard, size, class, face type and quantity per size.
  • Specify the material certificate: 3.1 as standard, 3.2 when third-party witnessing is required.
  • For low-temperature or sour service, state the design temperature and the NACE requirement on the order.
  • Confirm the coating: anti-rust oil, paint, galvanising or none.

Common specification mistakes

  • Ordering a grade without stating the certificate level — 3.1 is the baseline, not an upgrade.
  • Using 304/316 instead of the L grades on welded assemblies, then finding sensitisation at the weld.
  • Treating a PN rating and an ASME class as interchangeable; the pressure may match and the bolt pattern will not.
  • Specifying a material for sour service without checking the NACE hardness limit and heat-treatment condition.

Related products

Not sure which grade fits your service?

Send the service conditions →